Follow us :

Does Scan Motor RPM Equal LiDAR Frame Rate?

No. RPM is revolutions per minute. A sensor's useful scan rate and frame rate also depend on the optical arrangement, acquisition sequence and the definition of a frame.

A limited polygon calculation

If each of N facets provides one usable pass per revolution, ideal facet-pass rate is N multiplied by RPM and divided by 60. This relationship assumes the stated geometry and does not establish point rate, optical duty or the number of lines used in a frame.

What to confirm

Request a timing diagram linking motor feedback or reference events to useful acquisition. Identify any other scan axis, integration interval and data-processing convention used to form a frame. Confirm these at the complete sensor level.

Keep a separate timing definition for each rate

Record motor revolutions per second, useful optical passes per second, captured points per second and the number of completed frames per second as separate quantities. For each rate, identify the event or data unit being counted and the time interval used. A software frame can depend on an integration window or on how multiple scan lines or axes are combined.

Use a timing diagram to close the interface

Show the motor or encoder reference, any optical start-of-scan event and the acquisition window on one diagram. Ask which signal is available at the selected assembly and which relationship must be established by your system. Verify the agreed sequence with the actual optics, controller and acquisition settings. State the frame definition with any reported result so another engineer can reproduce the calculation instead of inferring it from an RPM value.

Related SolisMotor resources

Technical references